This website uses cookies. By using this website and navigating further, you accept these cookies.
Detailed information about the use of cookies on this website is available here.
X

My Profile | View Project lists / Carts | Login
Bookmark this page | My Bookmarks
English | Deutsch | Français | Italiano
Home   |    Site Map   |    Locations Worldwide   |   Lineg   |    info@belimo.ch
Go
Energy Efficiency  |  Download Center  |  Phased Out Products  |  References  |  Interesting Links  |  Awards

General Air Solutions
Water Solutions
Sensors
Safety Solutions
Room & System Solutions
(incl. VAV and room temperature controllers)
Bus & System Integration

Bus systems at a glance
Belimo MP-Bus
LonWorks
BACnet / Modbus
KNX
MFT-Tools
Accessories

Belimo Cloud

Device selection tool

MP wiring calculator
Retrofit
Products A to Z
Send PDF data sheets

Get product brochures:
- in PDF format
Contact us!


Bus and communication systems Parameterizing devices / Tools

Belimo MP-Bus
LonWorks
BACnet / Modbus
KNX
MFT parameterizing tools
Accessories (bus communication)

Gateways MP-Bus

UK24BAC
UK24MOD
Fire protection with BACnet MS/TP and Modbus RTU

BKN230-24-MOD
BACnet / Modbus volumetric flow controller with sensor interface

VAV-Compact
BACnet / Modbus actuators with sensor interface

Actuators with sensor interface
Device selection tool
 


Gateway UK24BAC

With the UK24BAC gateway, up to 8 MP-Bus-capable Belimo actuators can be integrated on BACnet MS/TP (RS-485). The UK24BAC allows the actuators to be digitally controlled via the MP-Bus and send back their current operating status. The information on the controls and feedback is mapped in UK24BAC as BACnet objects. The UK24BAC gateway conforms to the BACnet Application Specific Controller (B-ASC) profile.

Sensor linking

One sensor can be connected per MP/MFT(2) actuator. This can be a passive resistance sensor (PT1000, NI1000 or NTC), an active sensor (output DC 0...10V), or a switching contact. This provides a straightforward way of digitising the analogue signal of the sensors with the Belimo actuator and transferring it via UK24BAC to the BACnet.

Very simple commissioning

The basic settings (address, baud rate, …) are configured with DIP switches. The MP-Bus assignment is automatically established and continuously updated.

Suitable actuators can be selected from the bus device selection tool.

 

  UK24BAC Product Information (2 mb)
Download Sektion


UK24BAC Firmware Upgrade
Gateway UK24MOD

With the UK24MOD gateway, up to 8 MP-Bus-capable Belimo actuators can be integrated on an RTU (RS-485) modbus. The UK24MOD allows the actuators to be digitally controlled via the MP-Bus and send back their current operating status. The information on the controls and feedback is managed in UK24MOD and processed with modbus commands

Sensor linking

One sensor can be connected per MP/MFT(2) actuator. This can be a passive resistance sensor (PT1000, NI1000 or NTC), an active sensor (output DC 0...10V), or a switching contact. This provides a straightforward way of digitising the analogue signal of the sensors with the Belimo actuator and transferring it via UK24MOD to the modbus.

Very simple commissioning

The modbus is parameterised with DIP switches (address, baud rate, bus termination, polarisation). The response delay can be optionally adjusted via a register entry.

The MP-Bus assignment is automatically established and continuously updated.

Suitable actuators can be selected from the bus device selection tool.

 

  UK24MOD Product information (2 mb)
Belimo field unit BKN230-24-MOD. Fire protection with BACnet MS/TP and Modbus RTU.



The integration of motorised fire dampers into BACnet MS/TP and Modbus RTU networks has now become simpler and less expensive. The new communication and power supply unit BKN230-24-MOD allows direct connection of the Belimo fire damper actuator via BACnet MS/TP or Modbus RTU to the central controller. The damper position and the status of the optional smoke detector can be visualised just as readily as any fault messages which may arise. This creates transparency, simplifies monitoring and thus enhances safety for people and property in buildings.

 

  BKN230-24-MOD
Product information (483 kb)


  Flyer: BKN230-24-MOD Integrierter Brandschutz mit Modbus RTU (1.4 mb)
BACnet / Modbus VAV-Compact volumetric flow controller with sensor interface

Compact volumetric flow controller with integrated interface for BACnet MS/TP and Modbus RTU (RS-485). The connection is made by cable. A version with RJ12 socket for error-free wiring is also available as an option.

Control

The volumetric flow controllers can be controlled via BACnet MS / TP, Modbus RTU or in hybrid mode (analog control, feedback via bus protocol).

Sensor interface

One active sensor or one switching contact can be integrated per actuator in the network. This makes conventional sensors capable of communication in the simplest way imaginable.

Parameterisation

In addition to such communications parameters as address, baud rate and transmission format, other actuator parameters such as running time and scaling can also be set with the Service Tool ZTH EU.

 

Device selection tool
BACnet / Modbus actuators with sensor interface

Actuator with integrated interface for BACnet MS/TP and Modbus RTU (RS-485) for the motorisation of dampers, characterised control and other valves. The connection is made by cable.

Control

The actuators can be controlled via BACnet MS / TP, Modbus RTU or in hybrid mode (analog control, feedback via bus protocol).

Sensor interface

One active or passive sensor or one switching contact can be integrated per actuator in the network. This makes conventional sensors capable of communication in the simplest way imaginable.

Parameterisation

In addition to such communications parameters as address, baud rate and transmission format, other actuator parameters such as running time and scaling can also be set with the Service Tool ZTH EU.

Variants with RJ12 connection socket

Actuators with RJ12 connection socket, without sensor connection, are available for the complete BACnet / Modbus assortment on demand. (Hybrid mode not available)

 

Device selection tool